Prüffeld

Extension of a technical building in Germany

Engineering, production, delivery, installation and initial commissioning of 3 emergency power gensets including all auxiliary drives and accessories. Max. tolerable sound pressure level with 3 gensets operating simultaneously ≤ 40 dB(A) measured at a distance of 30 m. Synchronised start-up of the gensets for magnetisation of 12 transformers.

 

Back



3 x 2900 kVA emergency power gensets

Diesel engine MTU
Type 20V 4000 G62
Output 2420 kW
Speed 1500 rpm

Generator A v Kaick
Type DIG 140 h/4
Output 3000 kVA
Voltage 10000 V at 50 Hz